HS10G3 Hybridscore Target
ProductSettings Description
Specifies the target Illumination Brightness in Percent. Default: 10
The target Illumination can be adjusted from 0% – 100% with this setting.
Color Temperature of the Target Illumination. Default: “Neutral”
The target illumination can be changed between “Cold” (6500K), “Warm” (2700K) and a “Neutral” white value in between. The “Legacy” option reflects a color temperature known from the former LS10G2 target of approximately 3000K.
Defines how long the paper feed motor moves in Meter. Default: 0.02 (2cm)
The Feed of the witness band after each shot can be adjusted with this setting.
Caution: The distance is set in meters!
Override the used microphone amplification
If a value other than “Inactive” is selected, the microphone gain is set to the corresponding value.
Supported Amplifications by HS10G3 are:
Override the used microphone voltage threshold to trigger shot detections
If a value other than 0 is set, the trigger levels are calculated based on this setting.
The two TriggerLevels are: 2.5V +- OverrideMicTrigger
Override the used FrameHit microphone amplification
If a value other than “Inactive” is selected, the microphone gain is set to the corresponding value.