Menu

Incorrect center with open measuring system (hunting)

Incorrect center with open measuring system (hunting)

The current version CUOS 2.2.1 in the device combination CU951 control unit and open measuring system AC13, which is also used for hunting, shows a center offset. This circumstance will be solved with the next version of CUOS, which is part of the SIUSLoader.

For current installations, you can go back to version CUOS 2.2.0 or correct it using the Y-correction in the CU951 control unit. If the correction is chosen, it does not have to be reset after the update to the corrected new version. This setting is automatically reset to the default value 0 with the update.