Menu

acousticeye.application

Acoustic Detection Systems

ProductSettings Description

ActiveMeasureAreaWidthInMeter

Width of the measuring area in which shots are calculated [m]

The active measuring area is the range in which the detection system should calculate and send shots to the AthleteMonitor.

The active measuring range is a rectangle, the width of which is defined with this parameter.

In the pictures below, the red rectangles are examples for active measurement areas of an open and a closed detection system:

   

 

ActiveMeasureAreaHeightInMeter

Height of the measuring area in which shots are calculated [m]

The active measuring area is the range in which the detection system should calculate and send shots to the AthleteMonitor.

The active measuring range is a rectangle, the height of which is defined with this parameter.

In the pictures below, the red rectangles are examples for active measurement areas of an open and a closed detection system:

   

 

CalibrationOffsetXInM

Device-specific X-coordinate calibration value [m]

Under construction

Device-specific horizontal correction value of calculated coordinates in meters. This setting is intended to correct target inaccuracies e.g. from inexactly mounted target pictures. This value is usually determined by measuring the deviation of multiple calibration shots.

Remark: The correction is always horizontal and a positive value is a correction to the right, independent of other settings like MountingFlipXZ or MountingRotZInDegree.

Example: value = 0.01

A shot with coordinates (X: 0.045 m / Y: -0.2 m) will be corrected and counted as (X: 0.055 m / Y: -0.2 m).
This value should be used when the target picture is mounted 1 cm right of the nominal position.

Default value: 0

 

CalibrationOffsetYInM

Device-specific Y-coordinate calibration value [m]

Under construction

Device-specific vertical correction value of calculated coordinates in meters. This setting is intended to correct target inaccuracies e.g. from inexactly mounted target pictures. This value is usually determined by measuring the deviation of multiple calibration shots.

Remark: The correction is always horizontal and a positive value is a correction to the right, independent of other settings like MountingFlipXZ or MountingRotZInDegree.

Example: value = 0.01

A shot with coordinates (X: 0.045 m / Y: -0.2 m) will be corrected and counted as (X: 0.045 m / Y: -0.19 m).
This value should be used when the target picture is mounted 1 cm above the nominal position.

Default value: 0

 

InternalRefTranslatXInM

Device internal X-offset [m]

Under construction

Warning: This setting must not be changed by customers. It is intended for OEM system manufacturers only.

Specifies the X distance from the detection systems reference point to the measurement systems reference point (in the detection system’s coordinate system orientation)

Default value: 0

 

InternalRefTranslatYInM

Device internal Y-offset [m]

Warning: This setting must not be changed by customers. It is intended for OEM system manufacturers only.

Specifies the Y distance from the detection systems reference point to the measurement systems reference point (in the detection system’s coordinate system orientation)

Device Default Value [m]
ACB01 0.896
ACB02 0.596
ACB03 0.9
ACE01 0.053
ACF01 0

 

InternalRefTranslatZInM

Device internal Z-offset [m]

Under construction

Warning: This setting must not be changed by customers. It is intended for OEM system manufacturers only.

Specifies the Z distance from the detection systems reference point to the measurement systems reference point (in the detection system’s coordinate system orientation)

Device Default Value [m]
ACB01 Not supported
ACB02 Not supported
ACB03 Not supported
ACE01 0.0854
ACF01 Not supported

 

MountingFlipXZ

Specifies whether the target is mounted back-side-front

Not supported for AcousticEye

This setting must be set when the target is mounted back-side-front (e.g. behind the wall). In this case the X-coordinates must be mirrored around the measurement system’s reference point (e.g. center for AousticBar)

Example: value = 1

A shot’s coordinates (X: 0.045 m / Y: -0.2 m) will be corrected to (X: 0.055 m / Y: +0.2 m) because the bullet hits the measurement system from its back side.

Device Default Value
ACB01 0
ACB02 0
ACB03 0
ACE01 Not supported
ACF01 0

 

MountingRefKind

Specifies the targets used reference point for mounting target pictures

Depending on which kind of target picture has to be mounted on the measurement system, this setting has to be set accordingly:

To mount a target picture with a center reference, the measurement system must be set to MountingRefKind = CenterReference.

To mount a target picture with an edge reference, the measurement system must be set to MountingRefKind = EdgeReference

Device Default Value
ACB01 Center Reference
ACB02 Center Reference
ACB03 Center Reference
ACE01 Edge Reference
ACF01 Center Reference

 

MountingRotZInDegree

Reflects the mounting type of the target (e.g. roof) as an angel [°]

In the event that the measuring system is mounted rotated (e.g. wall or roof), the mounting angle (in degree) must be applied to this setting to ensure that the coordinates are calculated correctly.

Examples:

Default: 0

 

OverrideMicAmplification

Override the used microphone amplification

If a value other than “Inactive” is selected, the microphone gain is set to the corresponding value.

Default is Inactive

 

OverrideMicTrigger

Override the used microphone voltage threshold to trigger shot detections

If a value other than 0 is set, the trigger levels are calculated based on this setting.

The two TriggerLevels are: 2.5V +- OverrideMicTrigger

Default is 0

 

SettlingDelayInMilliseconds

Prevents the target from detecting shots for the specified duration after a shot [ms]

After a shot is detected, the measuring system ignores any sensor signals for the next specified delay time. Any shot within this delay time will not be detected.

This setting can be useful if shots can cause unwanted interference signals, such as noise or objects flying through the measurement system (e.g. caused by a bad bullet catcher or walls reflecting shot noise in an indoor shooting range).

The maximum shot cadence will be reduced when increasing this setting.

Examples:

0 = deactivated: detect new shots as fast as possible

100 = 100 ms delay time / maximum shot cadence of 10 shots per second / 600 shots per minute.

Device Default Value
ACB01 0
ACB02 0
ACB03 0
ACE01 45
ACF01 300

 

ShotThemeliaLifetimeInS

How long shots remain stored on the server [s]

Detected shots, including their raw data, are stored on a server in the rack to allow later reconstruction of an incident. After the specified time, shots will be permanently removed from the server.

Example: value = 604800

Registered shots will be permanently removed from the server after 7 days